COMBINER BOX MONITORING SYSTEM
With real-time monitoring of the current, voltage, temperature, and switch status of the combiner box string, as well as remote data transfer using wired or wireless techniques, this device is intended for 1500V/1700V solar power systems.
DC arc detection integrated into the combination box for installation
PV system at 1500/1700V
Data transfer, histogram current, voltage, temperature, and electrical energy science presentation, decoration operation, and renovation effectiveness using RS485 and Power Line Communication (PLC)
Support computerized fact freezing, handle allocation, and log recording
Instead of tripping the power supply, the shunt time out unit can be pushed simultaneously, saving money. Support electrical line communication (PLC)mode; RS485 wiring is not an option
Type | FR-DCMG-MMPU / FR-DCMG-MMPZ | |
Current Measurement | ||
Maxinum Channels | 4 Multiple, Maxium 24 Channels | |
Input Current Range | A | -20~+20, -32~+32 |
Rated Current | A | -10~+10, -20~+20 |
Disorder | A | ≤ ±0.1 |
Offset Drift | A/°C | ≤ 0.005 |
Linearity | ≤ 1%FS | |
Voltage Measurement | ||
Input Voltage Range | 450V~1700V | |
Accuracy | 0.2,2‰ | |
Resolution | 1V | |
Temperature Measurement | ||
Temperature Sensor Input Quantity | 2 inputs | |
Sensor Type | NTC | |
Measuring Range | °C | -40~+125 |
Measurement Accuracy | °C | ±2 |
Temperature resolution | °C | 0.1 |
Switch Status Monitoring | ||
Number of digital inputs | 4 inputs | |
Input type | Dry contact input | |
Input voltage | V | DC 5 |
Local Display | ||
Voltage, current, humidity, etc. | Dot matrix LCD display | |
Working status indicator | 2 LEDs, respectively representing voltage, communication status | |
RS485 Communication Method | ||
Communication Protocol | Modbus-RTU | |
Communication Speed | 2400/4800/9600/19200/38400bps | |
Byte Format | 8N1,8O1,8E1 | |
Wireless Communication Method | ||
Wireless Solution | m | Power Line Communication (PLC) |
Communication distance distance | 400 | |
Network topology | Star | |
Main Control Power Supply Parameters | ||
Input voltage | V | 450V-1700V |
Maximum input current | A | 0.1 |
Power consumption | W | <10 |
Environment | ||
Working storage temperature | °C | -40~+85 |
Electromagnetic compatibility standard | ||
Certificate | CE Certificate |
COMBINER BOX MONITORING SYSTEM
With real-time monitoring of the current, voltage, temperature, and switch status of the combiner box string, as well as remote data transfer using wired or wireless techniques, this device is intended for 1500V/1700V solar power systems.
DC arc detection integrated into the combination box for installation
PV system at 1500/1700V
Data transfer, histogram current, voltage, temperature, and electrical energy science presentation, decoration operation, and renovation effectiveness using RS485 and Power Line Communication (PLC)
Support computerized fact freezing, handle allocation, and log recording
Instead of tripping the power supply, the shunt time out unit can be pushed simultaneously, saving money. Support electrical line communication (PLC)mode; RS485 wiring is not an option
Type | FR-DCMG-MMPU / FR-DCMG-MMPZ | |
Current Measurement | ||
Maxinum Channels | 4 Multiple, Maxium 24 Channels | |
Input Current Range | A | -20~+20, -32~+32 |
Rated Current | A | -10~+10, -20~+20 |
Disorder | A | ≤ ±0.1 |
Offset Drift | A/°C | ≤ 0.005 |
Linearity | ≤ 1%FS | |
Voltage Measurement | ||
Input Voltage Range | 450V~1700V | |
Accuracy | 0.2,2‰ | |
Resolution | 1V | |
Temperature Measurement | ||
Temperature Sensor Input Quantity | 2 inputs | |
Sensor Type | NTC | |
Measuring Range | °C | -40~+125 |
Measurement Accuracy | °C | ±2 |
Temperature resolution | °C | 0.1 |
Switch Status Monitoring | ||
Number of digital inputs | 4 inputs | |
Input type | Dry contact input | |
Input voltage | V | DC 5 |
Local Display | ||
Voltage, current, humidity, etc. | Dot matrix LCD display | |
Working status indicator | 2 LEDs, respectively representing voltage, communication status | |
RS485 Communication Method | ||
Communication Protocol | Modbus-RTU | |
Communication Speed | 2400/4800/9600/19200/38400bps | |
Byte Format | 8N1,8O1,8E1 | |
Wireless Communication Method | ||
Wireless Solution | m | Power Line Communication (PLC) |
Communication distance distance | 400 | |
Network topology | Star | |
Main Control Power Supply Parameters | ||
Input voltage | V | 450V-1700V |
Maximum input current | A | 0.1 |
Power consumption | W | <10 |
Environment | ||
Working storage temperature | °C | -40~+85 |
Electromagnetic compatibility standard | ||
Certificate | CE Certificate |