This bar serves to notify visitors of important updates
Smart Safety Protector
Smart Safety Protector
Key Features

1. PV module rapid shutdown meeting NEC 2017 & 2020 (690.12) requirements
2. Rapid Shutdown: Triggered within 30 seconds after the monitor loses power or the control switch manually turn off.
3. Module level data monitoring: 5 big datum including voltage,temperature, and in the way of snapshot collection
4. String break protection: active protection, all the PV module safety devices went into shutdown state within 5 seconds
5. Bidirectional PLC communication
  • Series TD

B2B does not have purchase function
Inquire
B2B does not add shopping cart function

Schematic  Diagram


e99dbca2-cb94-43aa-82b7-269a88366828



Function

Product Model   Number

FR-PVMS-TFSA

FR-PVMS-TFSB

FR-PVMS-TFSC

FR-PVMS-TFSH

FR-PVMS-TFSJ

Electrical Data

Max input/output operating voltage

60Vdc

60Vdc

60Vdc

80Vdc

80Vdc

Range of input/output operating voltage

20~60Vdc

20~80Vdc

Max continuous input/output current (Imax)

15Adc

18Adc

25Adc

18Adc

25Adc

Max input short circuit current (Isc)

38Adc

Max system   voltage (dc)

1500Vdc

Mechanical Data

Dimensions (without bracket, cable & connectors)

134 x 28 x 22mm

Cable cross   section size

TUV:4m², UL:12AWG

TUV:4m², UL:12AWG

TUV:6m², UL:10AWG

TUV:4m², UL:12AWG

TUV:6m², UL:10AWG

Cable   length

Input ±20cm,Output ±80cmcustomize

Connector

MC4 compatiblecustomize

Weight with   bracket, cable & connector

380 ± 20g

Environmental Data

Pollution degree

PD3

Operating   ambient temperature range

-40 ~ 75

Relative humidity range

4~100%

Ingress protection

IP68

PLC Communication Performance Data

Communication

Power Line   Carrier Communication

Max cable loop length

500m

Max PV modules under one transceiver module

512

Max PV strings under one transceiver module

32

Monitoring Performance Data

Voltage monitoring accuracy

± 0.2Vdc

Current monitoring accuracy

± 0.05Adc

Energy production metering accuracy

1%

Temperature monitoring accuracy

± 1

Compliance

Communication compliance

PLC

Safety compliance

NEC 2017 & 2020 (690.12);

UL1741;

CSA C22.2 No. 330-17; IEC/EN62109-1

Arc fault detection and protection

UL1699B

EMC

EN IEC 61000-6-1:2019

EN IEC 61000-6-3:2021

EN IEC 61000-6-8:2020




Typical Application Wiring Diagram



diagram



Mechanical  Drawing (mm)


MD



Detailed Feature List


Rapid Shutdown Features:

a.      Turn off trigger

b.      Reset

c.      Condition monitoring

 

Group string break protection function:

a.      Line break detection and protection

b.      Fault alarm

c.      Manually reset the disk


Component data monitoring function:

a.      PV module voltage monitoring

b.      Temperature monitoring

c.      PV plant data snapshot

*  Need Fonrich SafeSolar webapp