PV RSD-Tail Module
Fonrich PV Rapid Shutdown, Meets NEC 2017 & 2020(690.12) requirements, can rapidly or manually shut off the DC excessive voltage to defend the security of furnace and upkeep personnel in the tournament of a fireplace or Others crisis. At the identical time, it integrates Fonrich aspect monitoring, arc detection, and insulation detection applied sciences to reveal factor voltages, string currents, and battery panel temperature facts in actual time, and to realize string/parallel arc dangers and string insulation failure risks.
Installation
This user manual describes in detail the installation and operation of PV Rapid Shutdown System(PVRSS). Before installing and operating the equipment, you should read and understand all the instructions and be familiar with the relevant safety in relevant paragraphs.
Do not touch any parts other than those required for wiring during installation.
All electrical connections must meet the electrical standards of the country or region where they are located.
Make sure that the switch of the main controller or main control box is OFF during the configuration process.
Safety Precautions
To prevent personal injury and property damage, read this section carefully and observe all safety information at all times.
Requirements of operators Operators must have the following skills:
Knowledge of how PVRSS works and is operated.
Training in how to deal with the dangers and risks associated with installing, using electrical devices and installations.
Knowledge of and compliance with this document and all safety information
Application Diagram
Key Technical Specifications
Component | Model | Item | Parameter |
Tail Module | FR-PVMS-TSXX | Input operating voltage range | 12V-60V |
Accuracy of voltage measuring | ±0.2V | ||
Maximum System Voltage | 1500V | ||
Output voltage after shutdown | V(input)/100 | ||
Maximum cont. input current (Im) | 25A@55℃ | ||
Reverse current | 25A | ||
Accuracy of current measuring | ±0.05A | ||
Communication | PLC | ||
Communication capability, the length of cable loop | 500m | ||
Operating temperature | 40℃~ +80℃ | ||
Enclosure Rating | NEMA Type 6P/IP68 | ||
Safety Compliance | UL 1741 (Ed.2, Rev. February 15, 2018),CSA C22.2 No. 330-17 |
PV RSD-Tail Module
Fonrich PV Rapid Shutdown, Meets NEC 2017 & 2020(690.12) requirements, can rapidly or manually shut off the DC excessive voltage to defend the security of furnace and upkeep personnel in the tournament of a fireplace or Others crisis. At the identical time, it integrates Fonrich aspect monitoring, arc detection, and insulation detection applied sciences to reveal factor voltages, string currents, and battery panel temperature facts in actual time, and to realize string/parallel arc dangers and string insulation failure risks.
Installation
This user manual describes in detail the installation and operation of PV Rapid Shutdown System(PVRSS). Before installing and operating the equipment, you should read and understand all the instructions and be familiar with the relevant safety in relevant paragraphs.
Do not touch any parts other than those required for wiring during installation.
All electrical connections must meet the electrical standards of the country or region where they are located.
Make sure that the switch of the main controller or main control box is OFF during the configuration process.
Safety Precautions
To prevent personal injury and property damage, read this section carefully and observe all safety information at all times.
Requirements of operators Operators must have the following skills:
Knowledge of how PVRSS works and is operated.
Training in how to deal with the dangers and risks associated with installing, using electrical devices and installations.
Knowledge of and compliance with this document and all safety information
Application Diagram
Key Technical Specifications
Component | Model | Item | Parameter |
Tail Module | FR-PVMS-TSXX | Input operating voltage range | 12V-60V |
Accuracy of voltage measuring | ±0.2V | ||
Maximum System Voltage | 1500V | ||
Output voltage after shutdown | V(input)/100 | ||
Maximum cont. input current (Im) | 25A@55℃ | ||
Reverse current | 25A | ||
Accuracy of current measuring | ±0.05A | ||
Communication | PLC | ||
Communication capability, the length of cable loop | 500m | ||
Operating temperature | 40℃~ +80℃ | ||
Enclosure Rating | NEMA Type 6P/IP68 | ||
Safety Compliance | UL 1741 (Ed.2, Rev. February 15, 2018),CSA C22.2 No. 330-17 |